Epoxy Coating Concrete Steel-Marine Structures Coating/Paint
|
|
For Details, Click Here to Send Us an Inquiry At: sales@epoxy-paint.cn to see if this Epoxy Coating Concrete Steel-Marine Structures is right for your application. |
|
 |
|
COMMON USAGE High gloss industrial enamel offering good flow, hiding and protection for recommended surfaces in mild to moderately
severe exposures. Not for use on surfaces that are continually wet or sweat frequently.
COLORS Refer to Honest Color Guide.
FINISH Gloss
PERFORMANCE CRITERIA Extensive test data available. Contact your Honest representative for specific test results.
Published technical data and instructions are subject to change without notice. The online catalog
should be referenced for the most current technical data and instructions or you may contact your Honest representative
for current technical data and instructions.
COATING SYSTEM
PRIMERS Steel: Series 1, 10, 37H, 66, N69, 88HS, 530
Galvanized Steel and Non-Ferrous Metal: Series 66 or N69. Note: Series 66 or N69 exterior exposed for 3 weeks or longer
requires an epoxy-polyamide intermediate coat or scarification prior to topcoating with 2H. Brush blasting with fine
abrasive is the preferred method of scarification.
Drywall: 51-792
Wood: Series 36-603
SURFACE PREPARATION
ALL SURFACES Must be clean, dry and free of oil, grease and other contaminants. Remove rust and paint not tightly bonded. Spot prime.
TECHNICAL DATA
VOLUME SOLIDS 49.0 ± 2.0% †
RECOMMENDED DFT 1.5 to 3.5 mils (40 to 90 microns) per coat. Note: Number of coats required will vary depending on color, substrate
(surface) and other variables. Contact your Honest representative.
CURING TIME Temperature To Touch To Handle To Recoat
75°F (24°C) 6-9 hours 10-16 hours 12-24 hours
Curing time varies with surface temperature, air movement, humidity and film thickness.
Water Tank Exteriors: Five days or more curing time required before filling with water.
VOLATILE ORGANIC COMPOUNDS Unthinned: 3.21 lbs/gallon (384 grams/litre)
Thinned 8%: 3.45 lbs/gallon (413 grams/litre) †
THEORETICAL COVERAGE 786 mil sq ft/gal (19.3 m²/L at 25 microns). See APPLICATION for coverage rates. †
NUMBER OF COMPONENTS One
PACKAGING 55 gallon (208.2L) drums, 5 gallon (18.9L) pails and 1 gallon (3.79L) cans.
NET WEIGHT PER GALLON 9.60 ± 0.25 lbs (4.35 ± .11 kg) †
STORAGE TEMPERATURE Minimum 20°F (-7°C) Maximum 110°F (43°C)
TEMPERATURE RESISTANCE (Dry) Continuous 200°F (93°C) Intermittent 250°F (121°C)
SHELF LIFE 24 months at recommended storage temperature.
FLASH POINT - SETA 100°F (38°C)
HEALTH & SAFETY Paint products contain chemical ingredients which are considered hazardous. Read container label warning and Material
Safety Data Sheet for important health and safety information prior to the use of this product.
Keep out of the reach of children.
APPLICATION
COVERAGE RATES Dry Mils (Microns) Wet Mils (Microns) Sq Ft/Gal (m²/Gal)
Suggested 1.5 (40) 3.0 (75) 524 (48.7)
Minimum 1.5 (40) 3.0 (75) 524 (48.7)
Maximum 3.5 (90) 7.0 (180) 225 (20.9)
Allow for overspray and surface irregularities. Film thickness is rounded to the nearest 0.5 mil or 5 microns. Application of
coating below minimum or above maximum recommended dry film thicknesses may adversely affect coating
performance. †
MIXING Stir thoroughly, making sure no pigment remains on the bottom of the can.
THINNING Use No. 1 Thinner or mineral spirits. For air spray, airless spray, brush or roller, thin up to 8% or 2/3 pint (302 mL) per
gallon.
Page 1 of 2
APPLICATION EQUIPMENT Air Spray
Gun Fluid Tip Air Cap Air Hose ID Mat’l Hose ID Atomizing
Pressure Pot Pressure
DeVilbiss MBC
or JGA E 78 5/16” or 3/8”
(7.9 or 9.5 mm)
3/8” or 1/2”
(9.5 or 12.7
mm)
40-70 psi
(2.8-4.8 bar)
10-20 psi
(0.7-1.4 bar)
Low temperatures or longer hoses require higher pot pressure.
Airless Spray
Tip Orifice Atomizing Pressure Mat’l Hose ID Manifold Filter
0.013”-0.017”
(330-430 microns)
2800-3500 psi
(193-241 bar)
1/4” or 3/8”
(6.4 or 9.5 mm)
60 mesh
(250 microns)
Use appropriate tip/atomizing pressure for equipment, applicator technique and weather conditions.
Roller: Use high quality synthetic nap covers. Use 1/4” to 1/2” (6.4 mm to 12.7 mm) nap, depending on surface
roughness.
Brush: Use high quality natural or synthetic bristle brushes.
SURFACE TEMPERATURE Minimum 40°F (4°C) Maximum 120°F (49°C)
The surface should be dry and at least 5°F (3°C) above the dew point.
CLEANUP Flush and clean all equipment immediately after use with the recommended thinner or mineral spirits.
† Values may vary with color. |
|
|
|
|
|
|
|
|
| |
|
| | |
 |
 |
 |
All Rights Reserved by
Feiyang ® Honest Joy Coating/Paint | |
 | |
|